Helicobacter Pylori Rapid Test Kit is available in the diagnosis of Helicobacter Pylori infections.
View The Details →
Bacterial vaginosis rapid test kit is available in the rapid qualitative analysis of sialidase levels in vaginal secretion.
View The Details →
Homocysteine (Hcy) rapid test kit is available in the precise and quick measurement of Hcy levels in serum.
View The Details →
Total Bilirubin (T-Bil) test kit is applied to measure the concentration of T-Bil in human serum or plasma.
View The Details →
The direct bilirubin (D-Bil) test kit provides a convenient and accurate measurement of concentration of D-Bil, also called conjugated bilirubin, in human plasma.
View The Details →
The aspartate aminotransferase (AST) test kit is intended for the accurate and direct quantitative measurement of AST activity in human plasma. AST measurement is useful in the diagnosis of liver disease and heart disease.
View The Details →
The alkaline phosphatase (ALP) test kit is intended for the accurate and direct quantitative measurement of ALP activity in human plasma. ALP measurement is useful in the diagnosis of liver, bile diseases and bone disorders.
View The Details →
The total protein (TP) test kit is intended for the accurate and direct quantitative measurement of TP in human plasma.
TP assay is clinically significant in diagnosis of many diseases. Liver protein synthesis disorder and kidney lesion can lead to protein loss and malnutrition, and thus the decrease of TP level, while cirrhosis and water deprivation can result in a remarkable increase.
View The Details →
The γ-Glutamyltransferase (GGT) test kit is intended for the accurate and direct quantitative measurement of GGT activity in human plasma. GGT measurement is useful in the diagnosis of hepatobiliary disease.
View The Details →
The albumin (ALB) test kit is intended for the accurate and direct quantitative measurement of ALB in human plasma.
View The Details →
The alanine aminotransferase (ALT) test kit is intended for the accurate and direct quantitative measurement of ALT in biological fluids such as serum and plasma. ALT measurement is useful in the diagnosis of certain liver disease and heart disease.
View The Details →
The Biomedia total bile acid(TBA) test kit is applied to measure the concentration of TBA in human plasma.
View The Details →
The urea (UA) test kit is intended for the accurate and direct quantitative measurement of UA concentration in human plasma.
View The Details →
The blood urine nitrogen (BUN) test kit is intended for the accurate and direct quantitative measurement of BUN content in human plasma.
View The Details →
The Cystatin C (Cys-C) test kit is intended for the accurate and direct quantitative measurement of Cys-C in biological fluids such as serum. Cys-C level is used as an indicator of glomerular filtration rate. The Cys-C measurement helps detect kidney disease at early stages and monitor the recovery of renal transplantation patients.
View The Details →
The creatinine (CRE) test kit is intended for the accurate and direct quantitative measurement of CRE in human plasma. Blood CRE is used to determine glomerular filtration rate (GFR), a measure of kidney function.
View The Details →
The glucose (GLU) test kit is intended for the accurate and direct quantitative measurement of GLU in human plasma.
The increase of GLU level usually results from diabetes, excessive intake of glucose, Cushing's syndrome or cerebral vascular accident (CVA). On the contrary, the decrease of GLU level can be caused by disease like insulinoma, insulin overdose, anorexia or congenital metabolism disorder of carbohydrate.
View The Details →
The Glycated Albumin(GA) test kit allows an accurate and quantitative in vitro measurement of glycated albumin (GA) and albumin (ALB) concentrations directly from human serum. GA measurement helps monitor blood glucose levels by showing damage to protein over the previous 2 – 3 weeks and is a more sensitive indicator of short-term variations.
View The Details →
The triglyceride (TG) test kit is intended for the accurate and direct quantitative measurement of TG in human plasma.
High TG level is usually found on patients who suffer from atherosclerosis, diabetes, nephrotic syndrome, hypothyroidism, hypercortisolism, fatty liver or pancreatitis. On the contrary, patients with hyperthyroidism, hypoadrenocorticism or hepatosis possess a lower level of TG compared with normal people.
View The Details →
The cholesterol (CHOL) test kit is intended for the accurate and direct quantitative measurement of CHOL in human plasma.
View The Details →
The Lipoprotein(a) (Lp(a)) test kit provides an convenient and accurate measurement of Lp(a) concentration in human serum or plasma.
View The Details →
The HDL-C test kit is intended for the direct quantitative measurement of high density lipoprotein cholesterol in human plasma.
View The Details →
The LDL-C test kit is intended for the direct quantitative measurement of low density lipoprotein cholesterol in human plasma.
View The Details →
The α-Hydroxybutyrate dehydrogenase (α-HBD) test kit is intended for the accurate and direct quantitative measurement of α-HBD activity in human plasma.
View The Details →
The lactic dehydrogenase (LDH) test kit is intended for the accurate and direct quantitative measurement of LDH activity in human plasma.
Increased LDH levels are usually observed in myocardial infarction, pulmonary infarction, liver disease, blood disease and muscle disease. The LDH test is widely used in the diagnosis of myocardial infraction and liver disease.
View The Details →
The creatine kinase-muscle/brain (CK-MB) test kit is intended for the accurate and direct quantitative measurement of CK-MB activity in human plasma.
View The Details →
The creatine kinase (CK) test kit is intended for the accurate and direct quantitative measurement of CK activity in human plasma.
Compared to AST or LDH test, CK test possesses higher specificity it is quite efficient in the diagnosis and monitoring of myocardial infarction when combined with CK-MB test.
View The Details →
Homocysteine (Hcy) test kit is available in the precise and quick measurement of Hcy levels in human plasma. Hcy measurement is applied as an indicator for hyperhomocysteinemia and cardiovascular disease (CVD).
View The Details →
The inorganic phosphorus (PHOS) test kit is intended for the accurate and direct quantitative measurement of inorganic phosphorus in human plasma. This test is mainly used in the diagnosis of renal dysfunction, bone disease and parathyroid disease.
View The Details →
The Magnesium (Mg) test kit is intended for the accurate and direct quantitative measurement of Mg in human plasma.
View The Details →
The Calcium (Ca) test kit is intended for the accurate and direct quantitative measurement of Ca in human plasma.
View The Details →